User Contributed Dictionary
Noun
- An engineering device that preheats a material prior to some other process
Extensive Definition
An air preheater or air heater is a general term
to describe any device designed to heat air before another process (for
example, combustion
in a boiler) with the
primary objective of increasing the thermal efficiency of the
process. They may be used alone or to replace a recuperative heat system or
to replace a steam coil.
In particular, this article describes the
combustion air preheaters used in large boilers found in thermal
power stations producing electric
power from e.g. fossil
fuels, biomasses or
waste.
The purpose of the air preheater is to recover
the heat from the boiler flue gas which
increases the thermal efficiency of the boiler by reducing the
useful heat lost in the flue gas. As a consequence, the flue gases
are also sent to the flue gas
stack (or chimney)
at a lower temperature, allowing simplified design of the ducting and the flue gas stack. It
also allows control over the temperature of gases leaving the stack
(to meet emissions regulations, for example).
Types
There are two types of air preheaters for use in steam generators in thermal power stations: One is a tubular type built into the boiler flue gas ducting, and the other is a regenerative air preheater. These may be arranged so the gas flows horizontally or vertically across the axis of rotation.Another type of air preheater is the regenerator
used in iron or glass manufacture.
Tubular type
Construction features
Tubular preheaters consist of straight tube bundles which pass through the outlet ducting of the boiler and open at each end outside of the ducting. Inside the ducting, the hot furnace gases pass around the preheater tubes, transferring heat from the exhaust gas to the air inside the preheater. Ambient air is forced by a fan through ducting at one end of the preheater tubes and at other end the heated air from inside of the tubes emerges into another set of ducting, which carries it to the boiler furnace for combustion.Problems
The tubular preheater ductings for cold and hot air require more space and structural supports than a rotating preheater design. Further, due to dust-laden abrasive flue gases, the tubes outside the ducting wear out faster on the side facing the gas current. Many advances have been made to eliminate this problem such as the use of ceramic and hardened steel.Many new circulating
fluidized bed (CFB) and bubbling
fluidized bed (BFB) steam generators are currently
incorporating tubular air heaters offering an advantage with
regards to the moving parts of a rotary type.
Dew point corrosion
Dew point corrosion occurs for a variety of reasons. The type of fuel used, its sulfur content and moisture content are contributing factors. However, by far the most significant cause of dew point corrosion is the metal temperature of the tubes. If the metal temperature within the tubes drops below the acid saturation temperature, usually at between 190°F (88°C)and 230°F (110°C), but sometimes at temperatures as high as 260°F (127°C), then the risk of dew point corrosion damage becomes considerable.Regenerative air preheaters
There are two types of regenerative air preheaters: the rotating-plate regenerative air preheaters (RAPH) and the stationary-plate regenerative air preheaters (Rothemuhle).Rotating-plate regenerative air preheater
The rotating-plate design (RAPH) In the
tri-sector design, the largest sector (usually spanning about half
the cross-section of the casing) is connected to the boiler hot gas
outlet. The hot exhaust gas flows over the central element,
transferring some of its heat to the element, and is then ducted
away for further treatment in dust
collectors and other equipment before being expelled from the
flue
gas stack. The second, smaller sector, is fed with ambient air
by a fan,
which passes over the heated element as it rotates into the sector,
and is heated before being carried to the boiler furnace for
combustion. The third sector is the smallest one and it heats air
which is routed into the pulverizers and used to carry
the coal-air mixture to coal boiler burners. Thus, the total air
heated in the RAPH provides: heating air to remove the moisture
from the pulverised coal dust, carrier air for transporting the
pulverised coal to the boiler burners and the primary air for
combustion. The rotor
itself is the medium of heat
transfer in this system, and is usually composed of some form
of steel and/or ceramic
structure. It rotates quite slowly (around 3-5 RPM) to allow optimum
heat transfer first from the hot exhaust gases to the element, then
as it rotates, from the element to the cooler air in the other
sectors.
Construction features
In this design the whole air preheater casing is supported on the boiler supporting structure itself with necessary expansion joints in the ducting.The vertical rotor is supported on thrust
bearings at the lower end and has an oil bath lubrication, cooled
by water circulating in coils inside the oil bath. This arrangement
is for cooling the lower end of the shaft, as this end of the
vertical rotor is on the hot end of the ducting. The top end of the
rotor has a simple roller bearing to hold the shaft in a vertical
position.
The rotor is built up on the vertical shaft with
radial supports and cages for holding the baskets in position.
Radial and circumferential seal plates are also provided to avoid
leakages of gases or air between the sectors or between the duct
and the casing while in rotation.
For on line cleaning of the deposits from the
baskets steam jets are provided such that the blown out dust and
ash are collected at the bottom ash hopper of the air preheater.
This dust hopper is connected for emptying along with the main dust
hoppers of the dust collectors.
The rotor is turned by an air driven motor and
gearing, and is required to be started before starting the boiler
and also to be kept in rotation for some time after the boiler is
stopped, to avoid uneven expansion and contraction resulting in
warping or cracking of the rotor. The station air is generally
totally dry (dry air is required for the instrumentation), so the
air used to drive the rotor is injected with oil to lubricate the
air motor.
Safety protected inspection windows are provided
for viewing the preheater's internal operation under all operating
conditions.
The baskets are in the sector housings provided
on the rotor and are renewable. The life of the baskets depend on
the ash abrasiveness and corrosiveness of the boiler outlet
gases.
Problems
The boiler flue gas contains many dust particles (due to high ash content) not contributing towards combustion, such as silica, which cause abrasive wear of the baskets, and may also contain corrosive gases depending on the composition of the fuel. For example, Indian coals http://www.osc.edu/research/pcrm/emissions/coal.shtml generally result in high levels of ash, sulfur and silica in the flue gas. The wear of the baskets therefore is generally more than other, cleaner-burning fuels.In this RAPH, the dust laden, corrosive boiler
gases have to pass between the elements of air preheater baskets.
The elements are made up of zig zag corrugated plates pressed into
a steel basket giving sufficient annular space in between for the
gas to pass through. These plates are corrugated to give more
surface area for the heat to be absorbed and also to give it the
rigidity for stacking them into the baskets. Hence frequent
replacements are called for and new baskets are always kept ready.
In the early days, Cor-ten steel was
being used for the elements. Today due to technological advance
many manufacturers may use their own patents. Some manufacturers
supply different materials for the use of the elements to lengthen
the life of the baskets.
In certain cases the unburnt deposits may occur
on the air preheater elements causing it to catch fire during
normal operations of the boiler, giving rise to explosions inside
the air preheater. Sometimes mild explosions may be detected in the
control
room by variations in the inlet and outlet temperatures of the
combustion air.
Stationary-plate regenerative air preheater
The heating plate elements in this type of regenerative air preheater are also installed in a casing, but the heating plate elements are stationary rather than rotating. Instead the air ducts in the preheater are rotated so as to alternatively expose sections of the heating plate elements to the upflowing cool air.As indicated in the adjacent drawing, there are
rotating inlet air ducts at the bottom of the stationary plates
similar to the rotating outlet air ducts at the top of the
stationary plates.
Stationary-plate regenerative air preheaters are
also known as Rothemuhle preheaters, manufactured for over 25 years
by Balke-Dürr GmbH of Ratingen, Germany.
Regenerator
A regenerator consists of a brick checkerwork: bricks laid with spaces equivalent to a brick's width between them, so that air can flow relatively easily through the checkerwork. The idea is that as hot exhaust gases flow through the checkerwork, they give up heat to the bricks. The airflow is then reversed, so that the hot bricks heat up the incoming combustion air and fuel. For a glass-melting furnace, a regenerator sits on either side of the furnace, often forming an integral whole. For a blast furnace, the regenerators - commonly called Cowper stoves - sit separate to the furnace; a furnace needs no less than two stoves, but may have three. One of the stoves is 'on gas', receiving hot gases from the furnace top and heating the checkerwork inside, whilst the other is 'on blast', receiving cold air from the blowers, heating it and passing it to the blast furnace.See also
References
External links
- Overview & Technology of a continuously rotating cylinder air preheater
- Reducing Preheater Leakage Boosts Output and Availability from Power Engineering website, May 23. 2007.
- Air preheater cleaning and the direct improvement on Air Preheater and power station performance
- Air Heater inspection and repair on tubular air heaters